Re: Problem in Connecting with win 95 with Oracle WG 7.3 on NT
Date: 1996/12/07
Message-ID: <01bbe3dd$7e136b20$c4675fa8_at_hntp1.hinet.net>#1/1
I think you should have the same version of SQLNET in your client PC. ie Sql*net 2.3.
Kári Poulsen <kapo_at_olivant.fo> ¦¸¼g¤J¨ì¥DÃD
<01bbdeee$0a6207c0$14ebb6c2_at_henry>...
> Sounds like you need 32-bit ODBC on your window 95 client..
>
> Saud Kazim <saud.kazim_at_Cressoft.com.pk> wrote in article
> <saud.kazim.4.00193975_at_Cressoft.com.pk>...
> > We have an Oracle WG Server 7.3.2 on NT. We're using SQL*NET 2.3 on the
Server
> > and SQL*NET 2.2 on the client running Windows 95.
> > When we connect from the client using SQL*PLUS there isn't any problem.
> > But when try to connect through ODBC using Oracle's ODBC Driver 1.14 we
> > encounter the error ORA-01321
> > No Interface driver connected.
>
>
Received on Sat Dec 07 1996 - 00:00:00 CET