Re: Power Objects Remote Connection Problems

From: Kári Poulsen <kapo_at_olivant.fo>
Date: 1996/11/24
Message-ID: <01bbd99d$426308a0$14ebb6c2_at_henry>#1/1


Are you running sqlnet ver 1.xx or 2.xx?? Are you running OPO ver 1.xx or 2.0?

If your're running OPO ver 2.0 I think you have to have sqlnet 2.x running. AND the relevant *.POD file in your OPO directory. When you create a new session in OPO, you choose database type on the creation form. If the word 'Oracle' shows up, everything is OK, otherwise the same message appears if you try to manyally reconfigure a session..

Hope this helps..

Regards
 Kári Poulsen
 Faroese Broadcasting

Hagen Finley <hagen_at_violet.berkeley.edu> wrote in article <3297478B.2CA3_at_violet.berkeley.edu>...
> I have recently installed the OraWeb Server which includes a
> Workgroup 7.2 DB Server. I have successfully configured the SQL*Net
> interface between the PO7 Navigator on a remote WIN95 node such that I
> can establish a connection and read the NT server database. Also
> SQL*PLUS is able to read the remote server. However, when I try and
> connect to the same OWS server using the same alias from Power Objects
> (which is also installed on the WIN95 node) the connection fails:
>
> ORA-03121:no interface driver connected - function not performed
>
> I can't find any reference to this interface drive in any of the OPO
> docs. Is this "interface driver" a SQL*Net driver or a WIN95 network
> driver? How and where would one configure such a beast?
>
Received on Sun Nov 24 1996 - 00:00:00 CET