Hi Dong

A number of month ago (5-6) we experienced a 'similar' problem. We installed OAS 407/Oracle 805/NT SP4. Everything wen't smooth. Succeedingly we installed WebDB and a tool named "Oracle Workflow".

We got a similar message. It turned out that Oracle Workflow could not run if a SP >3 was installed. Succeedingly we tried to de-install SP4 (made a backup , , etc). So, we thought SP4 has been completely removed. Forget it  in our case). After installing SP 3 again, we had the same problems. Oracle Netherlands ( let's say the person in question) had to agree the best solution was to do """"Format C:"""", and install NT again with Oracle 805 with SP3.
In other words, I can not offer you a solution, but I think it's a good idea to share similar problems . You do not feel alone. Besides there is a possibilty that someone has a more constructive solution.

Greetings

Martin

Dong Chung <r42014_at_email.sps.mot.com> schreef in berichtnieuws 387FB3FB.394F9D93_at_email.sps.mot.com...
> Hi All,
>
> I installed the ORACLE APPLICATION SERVER 4.0.7 and when i tried to
> start it i received this error:
>
> "ORB is not responding. Please restart manually...
> OWS-20214: The OAS processes can not be started, because the CORBA orb
> processes can not be started."
>
> I found a post regarding the problem and it sounds like there is a
> compatibility issue between OAS 4.0.7 and NT Svc Pack 4.0.
>
> So I upgraded NT service pack to 6.0a version.
> But still have the same problem.
>
> Oracle Installation manual lists Svc pack 3.0 as a requirement.
>
> Would anyone have any idea of how I can solve this issue.
> Any help is appreciated.
>
> --
> D.C. Chung
Received on Sat Jan 15 2000 - 01:19:29 CET