Re: Des2K error: Pimary UI already exists

From: John Strange <jstrange_at_imtn.dsccc.com>
Date: 29 Jul 1998 12:17:25 GMT
Message-ID: <6pn3sl$12a$1_at_relay1.dsccc.com>


Get into the ER diagrammer.
Double click the Enity with the problem. Write down everything you delete/uncheck. Delete rowes from the UID tab.
Click the Attr tab and uncheck columns which are marked Primary. Run the retrofit
Replace the things you deleted if still missing.

Yong Huang (yong_at_shell.com) wrote:
: I reverse-engineered some tables in Design Editor (Generate | Capture
: Design of | Server Model From Database), tried to import them to
: Entity-Relationship Diagrammer (Table to Entity Retrofit) and got the
: error "A Primary Unique Identifier already exists for this Entity". But
: the table I wanted to retrofit only has two optional attributes
: (columns). Where does this Primary UI conflict come from? I really wish
: I could find a button at Table to Entity Retrofit to disable
: retrofitting any UI's. Please tell me how to solve this problem. Thanks
: a lot.

: Yong Huang
: Email:yong_at_shell.com

--
While DSC may claim ownership of all my ideas (on or off the job),
DSC does not claim any responsibility for them. Warranty expired when you
opened this article and I will not be responsible for its contents or use.