Re: Oracle reconnect problem
Date: 1995/05/16
Message-ID: <3palka$eg1_at_athos.cc.bellcore.com>#1/1
Michael Krolewski (mkrolew_at_pebbles.uswnvg.com) wrote:
> We are trying to run an application in 7X24 mode
> with connection to an Oracle 7.1 on a Sequent.
> During the course of testing, to simulate
> maintainance of the database, the Oracle database
> was shut down and the application was not.
> The application detected the shutdown of the
> Oracle database and started attempts to
> reconnect. When the Oracle database restarted,
> the application was not able to reconnect.
> The error message was invalid user login.
> Why?
> Other information. Application and Oracle
> are running on the same platform. Connections
> use the direct connection, not the TCP/IP
> connection.
> If the application is started after Oracle
> is started, the system works fine. Shutting
> down the application while Oracle is running
> also (re)connectes properly.
> Every once in awhile, the application does
> reconnect to Oracle after Oracle is restarted.
> Mike Krolewski
#### Did you release after you detected the shutdown? #### If not, your shadow process was probably still running, so it choked on the connect.