Re: Can't start third O7 instance

From: Mike D. Resnick <mresnick_at_world.nad.northrop.com>
Date: 1995/06/13
Message-ID: <DA4x3M.B38_at_gremlin.nrtc.northrop.com>#1/1


In article <DA47wK.1K5_at_gremlin.nrtc.northrop.com> I (Mike D. Resnick) wrote:
>Hello all -
>I'm having trouble starting up a third oracle 7.1.3.2 instance on my
>hp755. I get the following message when trying to start it:
>
>SQLDBA> startup
>ORA-07279: spcre: semget error, unable to get first semaphore set.
>HP-UX Error: 28: No space left on device
>Additional information: 1
>SQLDBA>
>
>However, I am able to start an Oracle 6.0.36 instance when the first two
>O7 instances are up. (The O6 instance is not up when I try to start the
>third O7 instance.)

After some testing, I have found that if I use sqldba (lmode) to startup the instance, mount the database, then open it, it will startup successfully. I just cant use the dbstart command. Any Clues???

>
>The machine should have plenty of semaphores (semmni=188,semmns=400,
>shmseg=120,shmmax=67108864,shmmni=320) and has 448mb RAM.
>
>Any help would be great - Thanks
>/--------------------------|---.----------------------------------|----------\
>| Michael D. Resnick | mresnick_at_world.nad.northrop.com |
>| Northrop Grumman Corporation | Voice: 310.332.7807 |
>| Military Aircraft - ILS LIS | Fax: 310.332.7816 |
>| One Northrop Ave. 2555/W6 |---------------------------------------------|
>| Hawthorne, CA 90250 |
>\------------------------------^
  Received on Tue Jun 13 1995 - 00:00:00 CEST

Original text of this message