Re: Windows 95 & Personal ORACLE 7 --- Is this resolved?
Date: 1995/04/27
Message-ID: <3nn177$1aas_at_rover.ucs.ualberta.ca>#1/1
In <3neda2$3c4_at_usenet.INS.CWRU.Edu>, hxg7_at_po.CWRU.Edu (Harley Green) writes:
>Upon trying to connect in PO7 under WIN95, I get the error:
>"ORA-03121: no interface driver connected..."
>
>ORACLE's press states that PO7 is Windows 95 ready. Does anyone know if
>the current rev (v7.1.4) of PO7 can run under Win95 or are we out of
>luck until Win95 goes production, and subsequently, ORACLE has to belly
>on up to the bar (read: no more excuses).
>
>Any input is greatly appreciated.
>-Harley Green
Ok Harley... input.
03121, 00000, "no interface driver connected - function not performed"
// *Cause: // *Action:
hmmm, a little anemic
(Unix version. It should be better once 7.1.6 is up and running)
Try this one...
ORA-03121 no interface driver connected - function not performed
Cause : This message occurs usually because the SQL*Net driver is not loaded into memory or there is a mismatch of the version of the driver. A user program linked with an obsolete library may also cause this message. Only programs provided by Oracle Corporation should use this interface. Action : If the message occurred during use of a program provided by Oracle Corporation, contact Worldwide Customer Support. If a user program caused the message, relink the program with current versions of the ORACLE libraries.
(Workgroup 2000 for OS/2)
Anyway, when you are trying to talk to your database, try connecting with a blank or a 2: (I think that indicates Interprocess Communication). Correct me if I'm wrong as I only use SQL*Net SPX and TCP.
As far as I can see this has nothing to do with Win95 as I can get this error a million ways from Sunday and on as many platforms (Mac, Windows, OS/2, SunOS 4.1.3 and Solaris 2.3, AIX 3.whatever and 4.whatever)
Ralph G. Young
Ralph.Young_at_UAlberta.Ca
Received on Thu Apr 27 1995 - 00:00:00 CEST