Re: Stopping sequence increments

From: Dave Mausner <dmausner_at_brauntech.com>
Date: 1997/07/01
Message-ID: <5pbfrl$d2s$1_at_client2.news.psi.net>#1/1


In article <42Ni3EAVSEuzEwAz_at_markhide.demon.co.uk>, Mark Hide <mch_at_markhide.demon.co.uk> wrote:
>
>Can anyone explain why and suggest a remedy for the following:
>
>In my master-detail form (Forms 4.5) where master block is query-only,
>detail block has a Primary Key field generated by a sequence.
>
>Why does the detail block generate a new record and thus increment the
>sequence for every new query on the master block. (many of the master
>records have no corresponding details).

if the trigger references sequence_name.NEWVAL then of course a new value is created every time. perhaps the wrong trigger type is in use.

--
Dave Mausner, Consulting Manager, Braun Technology Group, Chicago.