Oracle FAQ Your Portal to the Oracle Knowledge Grid
HOME | ASK QUESTION | ADD INFO | SEARCH | E-MAIL US
 

Home -> Community -> Usenet -> c.d.o.server -> Re: Re: Re: Re: Performance with one Sun T3 disk array

Re: Re: Re: Re: Performance with one Sun T3 disk array

From: <u577606201_at_spawnkill.ip-mobilphone.net>
Date: Fri, 23 Mar 2001 20:46:35 GMT
Message-ID: <r.985380395.1504425048@[12.36.152.147]>

> It's the same until you lose a drive and need to resilver. If you mirror
> then stripe the disk-pairs (RAID 1+0), then you only need to resilver
> a single drive. If you stripe then mirror (RAID 0+1), then you need to
> resilver the whole stripe.

Sounds to me like (hardware) mirror first, stripe second would be the preferred method in general. Is this correct?

John  

-- 
Spam protected message from: 
Sent by  john.beckerle  from ps in  field ge included in com
Posted via http://www.usenet-replayer.com/cgi/content/new
Received on Fri Mar 23 2001 - 14:46:35 CST