Re: Oracle clusterware related question

From: Marcin Przepiorowski <pioro1_at_gmail.com>
Date: Wed, 9 May 2012 10:03:56 +0100
Message-ID: <CAGdek=zhsdH_e_GcmO+GdZWsUnyaag5x0cL8DXR33_OC8V-oUA_at_mail.gmail.com>



On Tue, May 8, 2012 at 7:39 PM, Martin Berger <martin.a.berger_at_gmail.com> wrote:
> Agreed,
> I just never have seen it in real life; sorry for ignoring it.
>
> On Tue, May 8, 2012 at 8:23 PM, D'Hooge Freek <Freek.DHooge_at_uptime.be> wrote:
>>
>> With 11.2 that is no longer true.
>> When you have configured a system management board (eg ILO, DRAC, ELOM, ...) with the clusterware, a node has the possibility to kill a non responsive node by switching of the power.

Hi,

I know at least one configuration running on Solaris 10 x64 using IPMI and it is able to evict remote node in case of disk failure. Amir, I'm not sure if installing CRS on NFS is supported solution.

-- 
Marcin Przepiorowski
http://oracleprof.blogspot.com
--
http://www.freelists.org/webpage/oracle-l
Received on Wed May 09 2012 - 04:03:56 CDT