Re: powerpath, 11gr2, and ASM on sun Sparc

From: Harel Safra <harel.safra_at_gmail.com>
Date: Thu, 24 Feb 2011 21:06:39 +0200
Message-ID: <AANLkTin5frq-=Hi_qKQikvK7kS23rnCEkaRBCGmGpQAY_at_mail.gmail.com>



Up to 11.1 (including) you needed the voting disks and OCR disks to be the same. In 11.2 you can store them in ASM so that's not needed. I've run many Linux servers with 10g RAC on them that only had the voting/OCR identical and the data disks different. I've also installed 11.2 cluster with no regard to disk order.

What do you mean by "until we got asm headers stepped on"?

Harel Safra

On Thu, Feb 24, 2011 at 8:58 PM, Andrew Kerber <andrew.kerber_at_gmail.com>wrote:

> Thats what I always thought too until we got asm headers stepped on. There
> are also many notes about how to map the drives using multipath so they show
> up in the same spot on both nodes. Just not much on Powerpath. So I
> suspect this business of reading the headers doesn't always work for some
> reason.
>
>

--
http://www.freelists.org/webpage/oracle-l
Received on Thu Feb 24 2011 - 13:06:39 CST

Original text of this message