RE: IPMP testing on RAC cluster

From: Matthew Zito <mzito_at_gridapp.com>
Date: Tue, 28 Apr 2009 22:14:43 -0400
Message-ID: <C0A5E31718FC064A91E9FD7BE2F081B101D4B8B8_at_exchange.gridapp.com>


A better test would be to vlan out one of the ports on one of the nodes so that the layer 2 connection is still up, but the nodes can't communicate. This is on top of the normal pull the cable testing you describe.

Thanks,
Matt

--

Matthew Zito
Chief Scientist
GridApp Systems
P: 646-452-4090
mzito_at_gridapp.com
http://www.gridapp.com

-----Original Message-----

From: oracle-l-bounce_at_freelists.org on behalf of Ravi Gaur Sent: Tue 4/28/2009 11:03 AM
To: oracle list
Subject: IPMP testing on RAC cluster  

We are trying to run some tests to verify that our ipmp configuration in our RAC sandbox cluster works as desired. We've two nic cards for public and two for private and IPMP is configured for both. The plan is to physically plug them out (one at a time) and then plug them back in and ensure that everything works normally (ie no noticeable hiccups etc). Has anyone done this testing before and if so, are willing to share the test plan? Any queries/logs etc that might help. Here's some additional details if that helps -- 2 node RAC on Solaris 10
Oracle 10.2.0.4
Interfaces -- Public - bge0 and bge2; Private - bge1 and bge 3

TIA,

  • Ravi Gaur

--

http://www.freelists.org/webpage/oracle-l Received on Tue Apr 28 2009 - 21:14:43 CDT