Re: Standby on Same box

From: Howard Latham <howard.latham_at_gmail.com>
Date: Tue, 3 Feb 2009 12:41:35 +0000
Message-ID: <713d96d10902030441j13956960o4ab0b06ecda9aa68_at_mail.gmail.com>



Yes thats true - does it work ok?

2009/2/3 D'Hooge Freek <Freek.DHooge_at_uptime.be>:
> Yes, but if you are on 10g you could use flashback database to recover from a failover without having to rebuild your primary.
> At least, if your db files are still intact.
>
>
> Regards,
>
>
> Freek D'Hooge
> Uptime
> Oracle Database Administrator
> email: freek.dhooge_at_uptime.be
> tel +32(0)3 451 23 82
> http://www.uptime.be
>
>
> ________________________________________
> From: oracle-l-bounce_at_freelists.org [mailto:oracle-l-bounce_at_freelists.org] On Behalf Of Niall Litchfield
> Sent: dinsdag 3 februari 2009 13:32
> To: howard.latham_at_gmail.com
> Cc: oracle-l_at_freelists.org
> Subject: Re: Standby on Same box
>
> well for protection against loss of the original box, it's obviously not a great plan! It might provide some protection against logical corruption (the mythical 'junior dba' for example) if configured with a delay.
>
> As far as switchover/switchback goes - that operation doesn't involve a rebuild - though failover does.
>
> Niall Litchfield
>
>

-- 
Howard A. Latham
--