Message-ID: <c2213f680708300846t23e7a7f1p1c98fce3fb8cb81d@mail.gmail.com>


That's odd. These are the steps specific to MD Linus multipathing. You are using Hitachi multipathing drivers as I understand (I never had a chance to work with it). Patch 4679769 seems to be universal to all multipathing (it's discovered with power path). However, I have never applied it and always worked fine. Maybe it solves problem with block devices and not multipathing? For that, you should find Note 401132.1 useful.

On 8/30/07, rama.ari_at_accenture.com <rama.ari_at_accenture.com> wrote:
> Alex,
>
> Thanks for your prompt reply. Oracle suggested applying patch 4679769 as
> per Note # 343092.1

-- 
Alex Gorbachev, Oracle DBA Brewer, The Pythian Group